Updates and Patches for Users of Version 2.0
Updates, patches and bug fixes for ADELINE version 2.0 are available
for users from this page.
Note that these patches can only be used together with
a licenced copy of ADELINE 2.0.
To install a patch,
- Get the file(s) (zipped) from this page via your WWW browser
- Put it into a subdirectory called patches in the directory where
ADELINE is installed (e.g. c:\adeline\patches) You will need
to create this directory.
- Change to the directory where ADELINE is installed (e.g.
c:\adeline).
- Enter unzip patches\patchXX.zip
at the DOS prompt.
- Note: if you use pkunzip instead of the unzip utility that comes with
ADELINE, you must use pkunzip -d to make sure files are placed
into the proper directory.
Patch 16 (Version 2.00.16 of June 30, 1997)
Note: You must have version 2.00.15 already installed for this patch.
If you have a previous version installed, please refer to one of the patches
below. This patch does not update the version number shown on the interface
screens in order to minimize the size of the patch.
-
Patch16:
SUPERLITE: parameter files (*.def) do include the SUPERLINK information
RADLINK: Bug fixed for file handling, read/write files and calculation
RADLINK/SUPERLINK: calculation fixed when shading type is set to "none"
To download this patch, click on patch16.zip
(116KB)
Patch 14-16 (Thru Version 2.00.16 of June 30, 1997) including patch
13, 14 and 15.
Note: You must have version 2.00.12 already installed for this patch.
If you have a previous version installed, please refer to one of the patches
below.
-
Patch16:
SUPERLITE: parameter files (*.def) do include the SUPERLINK information
RADLINK: Bug fixed for file handling, read/write files and calculation
RADLINK/SUPERLINK: calculation fixed when shading type is set to "none"
Patch15:
SUPERLITE: parameter files (*.def) do include the SUPERLINK information
Patch14:
SUPERLINK: SUPERLINK files used to link the last SUPERLITE file which was
created when importing the Scribe Model. When saving the *.src file with a
new name this link was kept, thus no changes were saved when changing the
SUPERLITE options after opening such a file. Now the correct link to the
*.in file is saved..
RADLINK : major bug fix concerning file handling and calibration of data
PLINK : default options were changed: no abiente light (-av 0.0 0.0 0.0) is
used for calculations and one abient bounce (-ab 1) is used for low quality
caculation.
RADLINK : The number of abiente bounces can be set even for the low quality
calulations.
SUPERLITE Graphics: Plot is only possible if not more than 20 nodes are used
in each axis direction on the work surfaces. Work around: Use coarser grid
(see Edit|General... dialog)
Patch13:
RADLINK/SUPERLINK: A bug was fixed concerning file selection of the holiday
file.
RADLINK: A bug was fixed so multiple nodes can be selected for calculation know.
RADLINK: The function of the OK button within the RADLINK options/site
definition dialog was fixed.
To download this patch, click on pch14-16.zip
(760KB)
Patch 12 (Version 2.00.12 of December 17, 1996)
This patch requires
Note: You have to get patch11c.zip
or have version 2.00.11 already installed before applying this patch.
- RADLINK: A bug was fixed so that the worksurface data will
be read and rewritten when *.rif file are handled.
- SUPERLINK/RADLINK: The holiday-file dialog has been altered.
Holiday files can be edited from the dialog now. Please be aware
that the saved holiday file only is the handeled program parameter,
so save the file after changing the holiday list contens.
To download this patch, click on patch12.zip
(428KB)
Patch 11c (Version 2.00.11 of November 24, 1996)
Note:The LBNL distribution always includes the latest patches as
of the date of order. Check your floppy disk labels for the applicable
version number before downloading or applying any patches.
This patch fixes the following bugs:
Note: This is a complete patch you do not have to get any previous patch.
- SUPERLITE: This version provides a work-around for a problem that
appears when a model without enclosure surface is saved from the user
interface program: a wrong enclosure id is set for windows without
enclosure. The bug is not yet fixed, but this version prevents program
crash. Messages showing the enclosure id will be shown onscreen when
the model is saved. These messages can be ignored.
- SUPERLITE: Two bugs concerning electric lighting were fixed: first
luminaires were not rotated correctly when the model was rotated,
second electric lighting was not calculated when there was no natural
light from the outside. The remarks from patch 9 are still valid.
- SUPERLITE: Superlite Plots are now correct for models on the southern
hemisphere.
- PLINK: a bug was fixed concerning the conversion of 11xx layer from
Scribe-Modeller-Files.
To download this patch, click on patch11c.zip
(815 KB)
Known Problems and Unfixed Bugs
- SUPERLITE: As of version 2.00.09 a work-around exists for a problem that
appears when a model without enclosure surface is saved from the user
interface program: a wrong enclosure id is set for windows without
enclosure. Messages showing the enclosure id will be shown onscreen when
the model is saved. These messages can be ignored.
- SUPERLITE/PLINK: PLINK uses a tolerance of .2 SCRIBE-units to determine
if two surfaces are coplanar. This could lead to problems, especially
if luminaire groups are drawn very close to the ceiling of a model,
since the current SUPERLITE version does not allow luminaire groups to
be cut off from any other surface. This means, for instance, that if
the user draws in meters and a luminaire group is not more than 20 cm
under the ceiling, the luminaire group and the ceiling are considered
to be coplanar. This may lead to a program crash in SUPERLITE.
We will try to fix this problems a.s.a.p.
- SUPERLITE Graphics: Plot is only possible if not more than 20 nodes are
used in each axis direction on the work surfaces.
Work around: Use coarser grid (see Edit|General... dialog)
Last changed:November 25, 1996 ckehrlich@lbl.gov